Products

Load Break Switches

ABB OT200E12P SWITCH-DISCONNECTOR OT200E12P

Product Code: OT200E12P

3-pole, front operated, base mounted switch-diconnector with black IP65 handle and shaft, terminal bolt kit included

Technical Specifications

Impulse Withstand Voltage (kV/1.2µS) 12
Brand ABB
Cable Cross Section (mm²) 95
Control Element Colour Black
Conventional Free-Air Thermal Current - Ith (A) 200
Conventional Thermal Current - Ithe (A) 200
Degree of Protection - Handle IP65
Dimensions (mm) 150.5W x 150H x 82.5D
Handle Colour Black
Handle Dimensions (mm) 98W x 45H x 66D
Handle Length (mm) 65
Handle Material Plastic
Handle Type Pistol
Icw (kA/1s) - Short-time Withstand Current Rating 8
Included Handle, Shaft
Interlockable Yes
Main Circuit Electrical Connection Bolt Connection
Maximum Operational Voltage AC (V) 1000
Mode of Operation Front operated
Mounting Type Base Mount
NEMA Degree of Protection 1
No. of Poles 3
Operating Mechanism Mechanism Between the Poles 12
Operational Current AC-22A @ 380-415V (A) 200
Operational Current AC-22A @ 500V (A) 200
Operational Current AC-22A @ 690V (A) 200
Operational Current AC-23A @ 380-415V (A) 200
Operational Current AC-23A @ 500V (A) 200
Operational Current AC-23A @ 690V (A) 200
Operational Power AC-23A @ 400-415V (kW) 110
Operational Power AC-23A @ 500V (kW) 132
Operational Power AC-23A @ 690V (kW) 200
Poles 3P
Pollution Degree 3
Position of Mechanism Mechanism Between the Poles 12
Position of Operation Front Operated
Power Loss (W) 4/Pole
Rated Impulse Withstand Voltage (kV) 12
Rated Insulation Voltage (V) 1000
Rated Operational Current AC-21A 415V (A) 200
Rated Operational Current AC-22A 380-415V (A) 200
Rated Operational Current AC-22A 500V (A) 200
Rated Operational Current AC-22A 690V (A) 200
Rated Operational Current AC-23A 380-415V (A) 200
Rated Operational Current AC-23A 500V (A) 200
Rated Operational Current AC-23A 690V (A) 200
Rated Operational Power AC-23A 380-415V (kW) 110
Rated Operational Power AC-23A 400-415 V (kW) 110
Rated Operational Power AC-23A 500V (kW) 132
Rated Operational Power AC-23A 690V (kW) 200
Rated Operational Voltage (V) 1000
Rated Short-Time Withstand Current - Icw (kA) 8
Rated Short-time Withstand Current - Icw (kA/1s) 8
Rated Uninterrupted Current - Iu (A) 200
Shaft Dimensions (mm) 6W x 6H x 210D
Sizes (mm) 150W x 150.5H x 82.5D
Standards and Approvals IEC 60947-3
Suitable For Distribution Board Installation
Terminal Type Lug terminals
Terminal Width (mm) 20
Type Main Switch
Type of Handle Pistol
Type of Mounting Base Mount
Voltage (V) 1000

Documents

Products to compare:
Comparing Products